  • D671,D672,D673,D674,D675ËÅ·þ±ÈÀý·§

    ·¢²¼ÓÚ£º2025-12-29 14:41:23

    Æ·ÅÆÃû³Æ£ºMoog

    • ¶©»õÖÜÆÚ£º6-8ÖÜ
    • Á¢¼´¶©¹º

    ÖØÒª²ÎÊý£º

    Á÷Á¿·¶Î§£º30 L/min µ½ 3600 L/min

    ×î´óѹÁ¦£º350 bar(5000 psi)


    • ²úÆ·ÏêÇé
    Specifications

    D671 D672D673D674D675
    Control FunctionsFlow, Pressure, Flow&Pressure (p/Q), Axis (Position, Velocity, Force)
    Mounting PatternISO 4401 Size 05 (NG10)ISO 4401 Size 07 (NG16)ISO 4401 Size 08 (NG25)ISO 4401 Size 08 (NG25+)ISO 4401 Size 10 (NG32)
    Hydraulic Data
    Rated Flow at ?p 5 bar (75 psi) per land30 to 80 l/min150 to 250 l/min350 l/min550 l/min1000 - 1500 l/min





    (8 to 21.1 gpm) (39.6 to 66 gpm)(92.4 gpm)(145.3 gpm)(264.1 to 396.2 gpm)
    Maximum Flow180 l/min (47.5 gpm)600 l/min (158 gpm)1,500 l/min (396.2 gpm)1,500 l/min (396.2 gpm)3,600 l/min (951  gpm)
    Maximum Operating PressurePort P, A, B - 350 bar (5,000 psi)
    Port T with Y internal - depends on Pilot Valve
    Port T with Y external - 350 bar (5,000 psi)
    Step Response Time for 0 to 100% Step10 to 28 ms10 to 44 ms13 to 35 ms14  to 44 ms10 to 43 ms
    Electrical Data
    Supply Voltage24 VDC (18 to 32 VDC)
    Rated Signal Options+/-10 V, +/-10 mA and 4 to 20 mA
    Electrical Connectors6+PE, 11+PE
    Options
    InterfacesFieldbus Interface
    Additional Analoge Transducer Interfaces